Excalibur 366 Specifikace Strana 211

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 254
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 210
Troubleshooting
7-19
Table 7-1. LQS Troubleshooting Reference Chart (Continued)
Statistic Change in Value Cause(s) Recommendations
Number of
multiport/multidrop
resynchronizations
for each drop.
A timing slip or lengthy line disruption
occurred on the DDS circuit.
Investigate drops that have abnormally
high counts compared to other drops.
Run DAP diagnostic tests to isolate
circuit.
Number of times the
central DAP has
resynchronized the
entire network (global
resync count).
A timing slip or a lengthy line
disruption occurred on the DDS circuit,
most likely on the "control" leg of the
multidrop circuit.
Investigate drops that have abnormally
high counts compared to other drops.
Run DAP diagnostic tests to isolate
circuit. If problem is not found, run
DAP diagnostic tests on the "control"
leg.
Zobrazit stránku 210
1 2 ... 206 207 208 209 210 211 212 213 214 215 216 ... 253 254

Komentáře k této Příručce

Žádné komentáře